Fluke 714B Temperature Calibrator, 4 to 20 mA

714B_EN.webp

Part Number : 714B/EN

Brand : Fluke

Rugged construction with an easy-to-use interface, this single function thermocouple temperature calibrator measures 4 to 20mA signals while sourcing a temperature signal. Featuring intelligent shutdown, the calibrator remembers settings when powered down so you don't have to, and can replicate tests after powering back up.

View all

$ 1970.99


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke 714B Offers Delivering outstanding performance, this thermocouple calibrator presents durability and reliability. The calibrator is compact, lightweight, and offers an easy-to-use push-button interface. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. Features Measure temperature from TC output Simulate 17 different RTD types and resistance Operable with nine types of thermocouples Calibrate linear TC transmitter with mV source function Selectable °F or °C Dual inputs and backlit display for easy interpretation of measurements Thermocouple mini-jack termination Holster features test lead storage Power down settings remembered at power up for easy restart of tests Compatible with TPAK magnetic hanging system Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal Applications Petro-chemical Oil and gas Food and beverage Pharmaceutical

Downloads

Fluke_Temperature_Datasheet_18.pdf

pdf

Specifications

Range
  • -10 to 75 mV
  • 0 to 24 mA
Resolution
  • 0.001 mV
  • 0.01 mV
  • 0.001 mA
Accuracy (% of Reading + Floor)
  • 1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV (2 year)
  • 1 year: 0.01 % + 2 µA 2 year: 0.02 % + 4 µA
Accuracy (% of Output + Floor)
1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV
Maximum Voltage Applied Between any Terminal and Earth Ground or
30 V
Temperature
Operating: -10 to 50 °C Storage: -20 to 60 °C
Altitude
Operating: 6561' (2000 m) Storage: 39,370' (12,000 m)
Relative Humidity (% RH Operating without Condensation)
Non-condensing 90% (10 to 30 °C) 75% (30 to 40 °C) 45% (40 to 50 °C)
Vibration requirements
MIL-T-28800E, Class 2
Drop Test Requirements
3.2' (1 m)
IP Rating
IEC 60529: IP52 (with TC cap)
Electromagnetic Environment
IEC 61326-1, Portable
Safety
IEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power Supply
4 AA alkaline batteries/NEDA code: 15A, IEC code: LR6
Dimensions
0.4 x 3.3 x 7.4" (52.5 x 84 x 188.5 mm)
Weight
1.13 lbs (515 g)