Comes equipped with an infrared thermometer, this combo kit is built around this HVAC/R multimeter with temperature and microamps. The multimeter comes with temperature and microamp measurements, and the thermometer provides accurate measurements and yet easy to use, making this kit ideal for HVAC/R technicians.

View all

$ 291.59


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke 116 Offers Features Built-in thermometer Provides microamps to test flame sensors Low input impedance to helps prevent false readings due to ghost voltage Large white LED backlight for working in poorly lit areas Measures resistance, continuity, frequency, and capacitance Provides Min/Max/Average to record signal fluctuations Compact ergonomic design for one-handed operation Fits into optional ToolPak™ magnetic hanger for hands-free operation (sold separately) CAT III 600 V safety rated Applications HVAC/R Fluke 62 MAX Plus Infrared Thermometer Infrared thermometers are everything you'd expect from the experts in measuring temperature in transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents in hard to reach areas for repair and maintenance. If you've ever used an infrared thermometer, then you may have been fooled regarding the temperature reading. That's because IR thermometers project a measurement cone at a surface and take the average temperature of the cone at the target. Although most IR thermometers have a laser pointer, a laser is a line, not a cone, and you may think that you're getting temperature at the laser point only. It uses two rotating laser pointers that show you the size of the measurement area. It covers the temperature range from -22 to 1202°F (-30 to 650°C) with a response time less than 300 ms. The meters screen is located in a position and with a viewing angle (15°) that, in many cases, lets you see the display without having to move the thermometer from the measuring point. For most measurements, you simply pull the trigger once you've identified the measurement point. Features Dust and water-resistant: IP54 rated for dust and water resistance Drop tested: Rugged enough to survive a 9.8' (3 m) drop for your most harsh working environments Ergonomically designed for a more natural hand fit Small and lightweight: It clips to your tool belt or belt loop or easily fits into your tool box Distance to spot: Precise laser technology makes for more accurate and repeatable measurements Large, backlit display: Large screen makes data easier to read, even in dark areas Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements Alarm: Hi and Lo alarms for rapid display of measurements outside the limits Power: Powered by a single, standard AA battery Why IR Thermometers? Temperature is often the first indication of potential problems in electrical and mechanical applications. But how can you easily determine if an electrical panel has a hot spot, a motor is overheating or an HVAC/R system is inefficient? The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems. Applications Automotive Avionics Building automation Commercial Defence Military and aerospace HVAC/R Industrial Lighting Maintenance and repair Fluke TL75 Hard Point™ Test Lead Set Features One pair (red, black) of comfort grip probes 48" (1.22 m) PVC insulated test leads with right-angle shrouded banana plugs Recommended for general purpose measurements CAT II 1000 V, , 10 A rating CAT IV 600 V, CAT III 1000 V only with protective cap CSA listed Fluke 80BK-A Integrated DMM Temperature Probe Features Standard shrouded banana jack Convenient one piece construction Fluke 80AK-A Thermocouple Adapter Applications Low voltage (below 30 V AC, 60 V DC) Fluke 80PK-11 Type-K Velcro Thermocouple Temperature Probe Designed to be compatible with any temperature measuring instrument that accepts Type-K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Designed for hands free measurement of HVAC/R temperature measuring applications. Use multiple probes and leave in place for route based routine maintenance. Facilities Maintenance Challenges and the Fluke Solutions Facilities maintenance professionals face a wide range of challenges, from electrical and mechanical equipment uptime to overall safety concerns. It’s critical to maintain facilities and the associated assets at peak performance. Let's review the issues faced by maintenance managers, IT support, and electrical/mechanical technicians. Along with the Fluke solutions that offer to save you time and money while increasing efficiency and safety. Fluke makes reliable, rugged and accurate tools to maintain electromechanical systems, motors, pumps, electrical distribution systems and more to keep your world up and running. Learn More

Downloads

Fluke_Multimeter_Datasheet_35.pdf

pdf

Specifications

DC Millivolts
Range: 600.0 mV Resolution: 0.1 mV Accuracy: 0.5 % + 2
DC Volts
Range: 6, 60, 600 V Resolution: 0.001, 0.01, 0.1 V Accuracy: 0.5 % + 2
Auto Volts
Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts True RMS
Range: 600.0 mV Resolution: 0.1 V Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
AC Volts True RMS
Range: 6, 60, 600 V Resolution: 0.001, 0.01, 0.1 V Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer
Ohms
Range: 600 Ω, 6, 60, 600 kΩ, 6, 40 MΩ Resolution: 1 Ω, 0.001, 0.01, 0.1 kΩ, 0.001, 0.01 MΩ Accuracy: 0.9 % + 1
Diode Test
Range: 2.000 V Resolution: 0.001 V Accuracy: 0.9 % + 2
Capacitance
Range: 1000, nF, 10, 100, 9999, 100 to 1000, >1000 µF Resolution: 1 nF, 0.01, 0.1, 1 µF Accuracy: 0.9 % + 2, 1.9 % + 2, 5 % + 20
Lo-Z Capacitance
Range: 1 nF to 500µF Accuracy: 10 % + 2 typical
Temperature (Type-K Thermocouple)
Range: -40 to 752 °F (-40 to 400 °C) Resolution: 0.2 °F (0.1°C) Accuracy: 1 % + 18
AC µAmps True RMS (45 to 500 Hz)
Range: 600.0 µA Resolution: 0.1 µA Accuracy: 1.5 % + 3 (2.5 % + 3 >500 Hz
DC µAmps
Range: 600.0 µA Resolution: 0.1 µA Accuracy: 1.0 % + 2
Hz (V or A input)
Range: 99.99, 999.9 Hz, 9.999, 50.00 kHz Resolution: 0.01, 0.1 Hz, 0.001, 0.01 kHz Accuracy: 0.1 % + 2
Maximum Voltage Between any Terminal and Earth Ground
600 V
Display
Digital: 6,000 counts, updates 4/sec
Bar Graph
33 segments, updates 32/sec
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-40 to 140°F (-40 to 60°C)
Battery
9 V Alkaline, NEDA 1604A/IEC 6LR61
Battery Life
400 hours typical, without backlight
Surge Protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2