Fluke IRR1-SOL Solar Irradiance Meter, 0 to 1400 W/m2

IRR1-SOL.webp

Part Number : IRR1-SOL

Brand : Fluke

Designed to simplify the critical measurements needed for installing, testing, and maintaining solar panels or photovoltaic systems, the irradiance meter is an all-in-one, easy-to-use solution for solar installers. Its user interface and built-in temperature sensor make it easy to meet testing and documenting requirements.

View all

$ 337.76


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke IRR1-SOL OffersRugged and compact, this irradiance meter has an easy to read, high-contrast LCD screen that allows users to read measurements in direct sunlight making it perfect to bring it with you wherever you go. Easily meets the IEC 62446-1 requirements for testing, documenting, and maintaining photovoltaic systems with its simple user interface and built-in temperature sensor. In addition, the integrated compass and inclination sensor allow you to quickly measure and document roof and site orientation, pitch, and panel tilt while surveying, installing, or adjusting an installation. Features Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles Make instantaneous measurements to determine the Watts per square meter solar irradiation, required by IEC 62446-1 standard High contrast LCD with large numbers for easy readability in direct sunlight High precision mono-crystalline solar sensor: Instantaneous irradiance measurements up to 1400 W/m2 Two options for temperature measurement: Use the built-in temperature sensor or the external suction mount temperature probe to measure ambient and panel temperature Integrated compass: Measure and document rook or site orientation Inclination sensor: Know roof and PV panel tilt when surveying, installing, or adjusting the installation Photovoltaic system design and surveying To find the expected production at a site, determine your solar resource while taking shading into account. The solar resource is measured in peak sun hours: the number of hours per day with 1000 W generated per square meter of solar array. Location, time of day, season, and weather conditions all influence peak sun hours. Use this meter to determine the actual solar irradiance (Watts/m2) and shading at the site to develop a baseline. Measuring Once your system is installed, make sure it is operating as designed by measuring its electrical characteristics and the actual power output of the array. The performance of a photovoltaic array is based on its current-voltage (IV) curve. Use this meter to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Comparing and diagnosing Even when installed correctly, a photovoltaic system may not be producing the expected electrical output. In order to produce the expected output the system needs to receive the correct amount of irradiance energy to generate the DC voltage that is fed into the inverter. Applications Installing, commissioning, and troubleshooting of photovoltaic (PV) arrays Testing, documenting, and maintaining photovoltaic systems Measuring irradiance, temperature, inclination and direction of the solar array IV curve tracing

Downloads

IRR1-SOL.pdf_1.pdf

pdf

Specifications

Irradiance
Range: 0 to 1400 W/m2 Resolution: 1 W/m2 Accuracy: ±(5% + 5 digits)
Temperature
Range: -22 to 212°F (-30°C to 100°C) Resolution: 0.2°F (0.1°C)/1°F at <100°F Accuracy: ±2°F (±1°C) at 14 to 167°F (-10 to 75°C), ±4°F (±2°C) at -22 to 14°F (-30 to -10°C) and 167 to 212°F (75 to 100°C) Note: Temperature measurement response time: Approximately 30 seconds
Inclination Angle
Range -90 to 90° Resolution: 0.1° Accuracy: ±1.5° at -50 to 50° ±2.5° at -85 to -50° and 50 to 85° ±3.5° at -90 to -85° and 85° to 90°
Compass
Range: 0 to 360° Resolution: 1° Accuracy: ±7° Note A: Measurements valid for device inclination between -20 and 20° to horizontal. Outside that range on LCD will be shown "---" Note B: Result is referred to magnetic north
Environmental Conditions
Altitude: 0 to 6561.68' (0 to 2000 m) maximum Temperature: Operating: -4 to 122°F/-20 to 50°C (humidity <80%, noncondensing) Storage: -22 to 140°F/-30 to 60°C (humidity <80%)
Electromagnetic Compatibility (EMC)
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments
Protection
IP40
Power Supply
Type: 4 x AA alkaline batteries Life (typical): 50 hours (≤9000 readings) Auto power off: 30 minutes
Dimensions
5.90 x 3.14 x 1.37" (150 x 80 x 35 mm)
Weight
0.5 lbs (231 g)
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×
Chat with Us