Fluke 753 Documenting Process Calibrator

753.webp

Part Number : 753

Brand : Fluke

Equipped with a USB interface and communication cable, this process calibrator can source, simulate, and measure pressure, temperature, and electrical signals. Users can download procedures, lists, and instructions created with software, and even upload data for printing, archiving, and analysis.

View all

$ 8520.99


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke 753 Offers Powerful and efficient, this calibrator features source measurement capabilities for all common process parameters. Users can automate calibration procedures and capture data for documentation. Additionally, the process calibrator meets standards such as ISO 9000, FDA, EPA, and OSHA regulations. Features Full-featured documenting process calibrator for calibrating and troubleshooting Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters Powers transmitters during test using loop supply with simultaneous mA measurement Measures and sources pressure Allows you to creates and run automated as-found/as-left procedures to satisfy quality programs or regulations, and record and document results Holds up to a full week of downloaded procedures and calibration results Offers many flexible features like autostep, custom units, user-entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay Offers compatibility with DPCTrack2 and many other asset management software packages Bright white dual display for reading both sourced and measured parameters simultaneously Easy-to-use multi-lingual interface Gas gauge and rechargeable Li-Ion battery for 10 hour uninterrupted use

Downloads

753.pdf_31.pdf

pdf

Specifications

Voltage DC
  • Range/resolution: 100 mV, 3 V, 30 V, 300 V 1 year: 0.02% + 0.005 mV, 0.02% + 0.00005 V, 0.02% + 0.0005 V, 0.05% + 0.05 V 2 years: 0.03% + 0.005 mV, 0.03% + 0.00005 V, 0.03% + 0.0005 V, 0.07% + 0.05 V
  • Range/resolution: 100 mV, 1 V, 15 V 1 year: 0.01% + 0.005 mV, 0.01% + 0.00005 V, 0.01% + 0.0005 V 2 years: 0.015% + 0.005 mV, 0.015% + 0.0005 V, 0.015% + 0.0005 V
Voltage AC
Range/resolution: 3 (40 to 500 Hz)/0.001 V, 30 (40 to 500 Hz)/0.01 V, 300 (40 to 500 Hz)/0.1 V 1 year: 0.5% + 0.002 V, 0.5% + 0.02 V, 0.5% + 0.2 V 2 years: 1.0% + 0.004 V, 1.0% + 0.04 V, 1.0% + 0.2 V
Current DC
  • Range/resolution: 30 mA, 110 mA 1 year: 0.01% + 5 µA, 0.01% + 20 µA 2 years: 0.015% + 7 µA, 0.015% + 30 µA
  • Range/resolution: 22 mA (source), current sink (simulate) 1 year: 0.01% + 0.003 mA, 0.02% + 0.007 mA 2 years: 0.02% + 0.003 mA, 0.04% + 0.007 mA
Resistance
  • Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ 1 year: 0.05% + 50 mΩ, 0.05% + 50 mΩ, 0.05% + 500 mΩ, 0.1% + 10 Ω 2 years: 0.07% + 70 mΩ, 0.07% + 70 mΩ, 0.07% + 0.5 Ω, 0.15% + 15 Ω
  • Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ 1 year: 0.01% + 10 mΩ, 0.01% + 20 mΩ, 0.02% + 0.2 Ω, 0.02% + 3 Ω 2 years: 0.015% + 15 mΩ, 0.015% + 30 mΩ, 0.03% + 0.3 Ω, 0.03% + 5 Ω
Frequency
  • Range/resolution: 1.00 to 110.00 Hz/0.01 Hz, 110.1 to 1100.0 Hz/0.1 Hz, 1.101 to 11.000 kHz/0.001 kHz, 11.01 to 50.00 kHz/0.01 kHz 2 years: 0.05 Hz, 0.5 Hz, 0.005 kHz, 0.05 kHz
  • Range/resolution: 0.1 to 10.99 Hz, 0.01 to 10.99 Hz, 11.00 to 109.99 Hz, 110.0 to 1099.9 Hz, 1.100 to 21.999 kHz, 22.000 to 50.000 kHz 2 years: 0.01 Hz, 0.01 Hz, 0.1 Hz, 0.1 Hz, 0.002 kHz, 0.005 kHz
Data Log Functions
Measure functions: Voltage, current, resistance, frequency, temperature, pressure Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature Rate: 4 steps/second Trip detect: Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage: Selectable, 26 V Accuracy: 10%, 18 V minimum at 22 mA Maximum current: 25 mA, short circuit protected Maximum input voltage: 50 V DC
Step Functions
Source functions: Voltage, current, resistance, frequency, temperature Manual step: Selectable step, change with arrow buttons Autostep: Fully programmable for function, start delay, step value, time per step, repeat
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-4 to 140°F (-20 to 60°C)
Dust/Water Resistance
Meets IP52, IEC 529
Operating Altitude
9842' (3000 m) above mean sea level
Batteries
Internal battery pack Li-ion: 7.2 V, 4400 mAh, 30 Wh
Battery Life
>8 hours typical
Battery Replacement
Via snap-shut door without opening calibrator; no tools required
Side Port Connections
Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator
Data Storage Capacity
1 week of calibration procedures results
90 Day Specifications
The standard specification interval are 1 and 2 years Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2. Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
Dimensions
5.4 x 9.6 x 2.5" (136 x 245 x 63 mm)
Weight
2.7 lbs (1.2 kg)
Agency approvals
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993