Fluke 724 Temperature Calibrator

724.webp

Part Number : 724

Brand : Fluke

An easy-to-use temperature calibrator that can measure and source 12 thermocouple and seven RTD types, volts, and ohms, which allows users to test and calibrate a wide variety of temperature instruments. Additionally, this tool also handles high-speed pulsed RTD circuits and offers loop power.

View all

$ 3302.25


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke 724 OffersTest and calibrate all temperature sensors and transmitters in your plant with only this temperature calibrator. This instrument is easy-to-use, and sources and measures 12 thermocouple and seven RTD types, plus volts and ohms. Additionally, this tool as well handles high-speed pulsed RTD circuits and provides loop power. It features a dual-line measure/source display that allows users to source temperature and view loop current simultaneously and a "no menus" controls. Features Easy to read dual display lets you view input and output simultaneously Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters Perform fast linearity tests with 25% and 100% steps Execute remote tests with auto step and auto ramp Power transmitters during test using loop power supply with simultaneous mA measurement Store frequently-used test setups for later use Backlight lets you work in poor light Large battery capacity of four AA cells Battery door for easy changes A compact, streamlined shape that makes it easy to carry A rugged, reliable design that stands up to field use

Downloads

724.pdf_4.pdf

pdf

Specifications

Voltage DC
  • 30.000 V: 0.02% + 2 counts (upper display) 20.000 V: 0.02% + 2 counts (lower display) 100.00 mV: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
  • 100.00 mV: 0.02% +2 counts 10.000 V: 0.02% +2 counts –10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA: 0.02% + 2 counts
Resistance
  • 0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
  • 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage: 24 V Accuracy: 10% Maximum current: 22 mA, short circuit protected
Step Functions
Source functions: voltage, resistance, temperature Steps: 25% of range, 100% of range
Operating Temperature
14 to 131°F (–10 to 55°C)
Storage Temperature
-4 to 160°F (–20 to 71°C )
Humidity (without condensation)
90% = 50 to 86°F (10 to 30°C) 75% = 86 to 104°F (30 to 40°C) 45% = 104 to 122°F (40 to 50°C) 35% = 122 to 131°F (50 to 55°C)
Safety Rating
CSA C22.2 No. 1010.1:1992
EMC
EN50082-1:1992 and EN55022:1994 Class B
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×