Fisher Emerson First-Stage Regulator R622H-HGK, Inlet - FPOL, Outlet - 1/2 FNPT

R622H.webp

Part Number : R622H-HGK

Brand : Fisher

Type R622H – High Flow First-Stage regulator with multiple end connections and adjustable outlet pressure spring ranges. A large 3/4 in. FNPT drip-lip vent reduces the chance of blockage by freezing rain or sleet when properly installed with the vent pointing down. Each Type R622H is equipped with a corrosion-resistant internal relief valve that provides high capacity relief and a travel stop on the closing cap. Its size and configuration make it ideal for under-the-dome installations.

View all
Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Types R122H, R222H and R622H First-Stage Regulators are Underwriters Laboratories (UL®) listed regulators designed for Two-Stage LPG systems. These First-Stage regulators reduce tank pressure to a lower pressure (usually 10 psig / 0.69 bar) for a Second-Stage regulator. Maximum allowable inlet pressure is 250 psig / 17.2 bar. Fisher™ First-Stage regulators are painted red for easy identification. Vents are screened with standard orientation over the outlet. The Types R122H, R222H and R622H regulators have a temperature rating of -20 to 160°F / -29 to 71°C, but have passed Fisher internal testing for lockup, relief start-to-discharge and reseal down to -40°F / -40°C. The design’s superior relief performance exceeds UL requirements and provides double failure overpressure protection (pressure downstream of the second regulator will be limited close to 2 psig / 0.14 bar, even if both regulators are damaged) when used with R600 Series Second-Stage regulator. Corrosion and wear resistant materials and stainless steel internal parts provide a recommended replacement life of 20 years. A large fabric reinforced diaphragm with molded lips provide precise regulation. The large precision machined orifice assists in minimizing freeze problems. 1/8 in. inlet and outlet gauge taps allow easy system testing. Large inlet and outlet wrench fetter lockup performance and durability in contaminated gas. The vent is with 3/8 in. NPT for easy installation of vent piping.

Type R622H

High Flow First-Stage regulator with multiple end connections and adjustable outlet pressure spring ranges. A large 3/4 in. FNPT drip-lip vent reduces the chance of blockage by freezing rain or sleet when properly installed with the vent pointing down. Each Type R622H is equipped with a corrosion-resistant internal relief valve that provides high capacity relief and a travel stop on the closing cap. Its size and configuration make it ideal for under-the-dome installations.

Downloads

Fisher Regulators Datasheet

Specifications

CAPACITIES (PROPANE)(1)(3) BTU / hr
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
2000000
CAPACITIES (PROPANE)(1)(3) SCMH
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
22.5
CAPACITIES (PROPANE)(1)(3) kg/hr
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
38.96
INLET CONNECTION, IN
FPOL
OUTLET CONNECTION, IN
1/2 FNPT
OUTLET ADJUSTMENT RANGE, psig
4 to 6
OUTLET ADJUSTMENT RANGE, bar
0.28 to 0.41
OUTLET PRESSURE SETTING, psig
5
OUTLET PRESSURE SETTING, bar
0.34
Brand
Fisher
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×
Chat with Us