Fisher Emerson First-Stage Regulator R622H-BGJ, Inlet - 1/2 FNPT, Outlet - 1/2 FNPT

R622H.webp

Part Number : R622H-BGJ

Brand : Fisher

Type R622H – High Flow First-Stage regulator with multiple end connections and adjustable outlet pressure spring ranges. A large 3/4 in. FNPT drip-lip vent reduces the chance of blockage by freezing rain or sleet when properly installed with the vent pointing down. Each Type R622H is equipped with a corrosion-resistant internal relief valve that provides high capacity relief and a travel stop on the closing cap. Its size and configuration make it ideal for under-the-dome installations.

View all
Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Types R122H, R222H and R622H First-Stage Regulators are Underwriters Laboratories (UL®) listed regulators designed for Two-Stage LPG systems. These First-Stage regulators reduce tank pressure to a lower pressure (usually 10 psig / 0.69 bar) for a Second-Stage regulator. Maximum allowable inlet pressure is 250 psig / 17.2 bar. Fisher™ First-Stage regulators are painted red for easy identification. Vents are screened with standard orientation over the outlet. The Types R122H, R222H and R622H regulators have a temperature rating of -20 to 160°F / -29 to 71°C, but have passed Fisher internal testing for lockup, relief start-to-discharge and reseal down to -40°F / -40°C. The design’s superior relief performance exceeds UL requirements and provides double failure overpressure protection (pressure downstream of the second regulator will be limited close to 2 psig / 0.14 bar, even if both regulators are damaged) when used with R600 Series Second-Stage regulator. Corrosion and wear resistant materials and stainless steel internal parts provide a recommended replacement life of 20 years. A large fabric reinforced diaphragm with molded lips provide precise regulation. The large precision machined orifice assists in minimizing freeze problems. 1/8 in. inlet and outlet gauge taps allow easy system testing. Large inlet and outlet wrench fetter lockup performance and durability in contaminated gas. The vent is with 3/8 in. NPT for easy installation of vent piping.

Type R622H

High Flow First-Stage regulator with multiple end connections and adjustable outlet pressure spring ranges. A large 3/4 in. FNPT drip-lip vent reduces the chance of blockage by freezing rain or sleet when properly installed with the vent pointing down. Each Type R622H is equipped with a corrosion-resistant internal relief valve that provides high capacity relief and a travel stop on the closing cap. Its size and configuration make it ideal for under-the-dome installations.

Downloads

Fisher Regulators Datasheet

Specifications

CAPACITIES (PROPANE)(1)(3) BTU / hr
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
2100000
CAPACITIES (PROPANE)(1)(3) SCMH
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
23.6
CAPACITIES (PROPANE)(1)(3) kg/hr
1. Based on 30 psig / 2.1 bar inlet pressure and 20% droop. 3. Metric conversion is based on 2516 BTU/ft3 of gas at 60°F / 16°C.
40.91
INLET CONNECTION, IN
1/2 FNPT
OUTLET CONNECTION, IN
1/2 FNPT
OUTLET ADJUSTMENT RANGE, psig
8 to 12
OUTLET ADJUSTMENT RANGE, bar
0.55 to 0.83
OUTLET PRESSURE SETTING, psig
10
OUTLET PRESSURE SETTING, bar
0.69
Brand
Fisher
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×
Chat with Us