Hanna Instruments Multiparameter Waterproof Meter with GPS, Turbidity, and Basic Probe (4m, 13'), 230V AC, HI9829-01042

Part Number : HI9829-01042

Brand : Hanna Instruments

The HI9829 is a waterproof multiparameter meter that monitors up to 14 water quality parameters, including pH, ORP, conductivity, dissolved oxygen, turbidity, and temperature. Its microprocessor-based probe transmits digital readings and can log data independently. Optional GPS enables location tracking, and the system is easy to set up, customizable, and comes with all necessary accessories in a durable carrying case.

View all

$ 6000


Quantity



Description
Specifications
Downloads
Related products

Description

The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

Built in GPS Receiver

Two probes to choose from (Basic or Logging)

The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default the HI9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

HI7609829 Basic Probe

  • Digital probe that is less than 2 inches in diameter
  • 3 color-coded sensor inputs
  • IP68 rating for continuous immersion in water
  • Multistrand –mulitconductor cable rated for 150 lbs (intermittent use)
  • Available with 4, 10, or 20 meter cable
  • Weighted shield protects all sensors

 

HI7629829 Autonomously Logging Probe

  • Same as basic probe but with logging capability
  • Logs data independent of HI9829 meter
  • Operates on 4 “AA” batteries for up to 70 days*
  • Stores up to 140, 000 single parameter readings or 35, 000 for all parameters
  • Logs data from 1 second to 3 hours
  • Choose to be supplied with EC or EC/Turbidity sensor
  • Supplied with USB cable for direct connection to Window’s compatible PC

*All channels logging at 10 minute intervals with no averaging

Downloads

MAN9829_07_19.pdf

pdf

Specifications

SKU
HI9829-01042
Name
HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Basic probe - with turbidity-4m (13')
pH Range
0.00 to 14.00 pH
pH Resolution
0.01 pH
pH Accuracy
±0.02 pH
pH Calibration
automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range
±2000 mV
ORP Resolution
0.1 mV
ORP Accuracy
±1.0 mV
ORP Calibration
automatic at one custom point (relative mV)
mV Range
±600.0 mV
mV Resolution
0.1 mV
mV Accuracy
±0.5 mV
EC Range
0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution
Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.
EC Accuracy
±1% of reading or ±1 µS/cm whichever is greater
EC Calibration
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range
0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolution
Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt
TDS Accuracy
±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration
based on conductivity or salinity calibration
Salinity (PSU) Range
0.00 to 70.00 PSU
Salinity (PSU) Resolution
0.01 PSU
Salinity (PSU) Accuracy
±2% of reading or ±0.01 PSU whichever is greater
Salinity (PSU) Calibration
based on conductivity calibration
Salinity (Seawater Sigma) Range
0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Resolution
0.1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Accuracy
±1 σt, σ₀, σ₁₅
Salinity (Seawater Sigma) Calibration
based on conductivity or salinity calibration
Resistivity Range
0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm
Resistivity Resolution
dependent on resistivity reading
Resistivity Calibration
based on conductivity calibration
Dissolved Oxygen Range
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved Oxygen Resolution
0.1%; 0.01 ppm (mg/L)
Dissolved Oxygen Accuracy
0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3
Dissolved Oxygen Calibration
automatic one or two points at 0 and 100% or one custom point
Turbidity Range
0.0 to 99.9 FNU; 100 to 1000 FNU
Turbidity Resolution
0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
Turbidity Accuracy
±0.3 FNU or ±2 % of reading, whichever is greater
Turbidity Calibration
Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
Temperature Range
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
Temperature Resolution
0.01 K, 0.01 °C, 0.01 °F
Temperature Accuracy
±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration
automatic at one custom point
Temperature Compensation
automatic from -5 to 55 °C (23 to 131 °F)
Ammonium Resolution
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Ammonium Accuracy
±5 % reading or 2 ppm
Ammonium Calibration
1 or 2 point, 10 ppm and 100 ppm
Chloride Range
0.6 to 200.0 ppm Cl (as Cl- )
Chloride Resolution
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Chloride Accuracy
±5 % of reading or 2 ppm
Chloride Calibration
1 or 2 point, 10 ppm and 100 ppm
Nitrate Range
0.62 to 200.0 ppm Ni (as NO3 - -N)
Nitrate Resolution
0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
Nitrate Calibration
1 or 2 point, 10 ppm and 100 ppm
Logging Memory
44,000 records (continuous logging or log-on-demand of all parameters)
Logging Interval
one second to three hours
Connectivity
USB (with HI 929829 software)
Battery Type/Life
1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration
IP Protection
IP67
Environment
0 to 50°C (32 to 122°F); RH max 100%
Dimensions
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
Weight
750 g (26.5 oz.)
GPS
12 channel receiver 10 m (30 ft) accuracy
Voltage
Choose the voltage require to operate the valve.AC stands for alternating current, DC for direct current.