Low to Intermediate Temperature Couplants
Product
|
Compliance
|
Operating Range
|
Environment
|
Auto Ignition Temperature
|
Viscosity
|
Packaging
|
Halogens and Sulfur
|
Removal
|
pH
|
Corrosion Characteristic
|
---|
ASTM F519, FAA-AC # 25-29 (glycerin-free), NAVSHIPS 250-1500, Nuclear grade (less than 50 ppm Halogens & Sulfur), P91 Steel Inspection – meets requirement for a water-free couplant, SME Boiler & Pressure Vessel Code (T-533) | -60°F to 350°F (-51°C to 176°C) | The most environmentally friendly commercial ultrasonic couplant available. | 700°F / 371°C | High viscosity stiff gel like fluid | 1 gal / 3.8 liter, with one bottle, dispensing cap | Less than 50 ppm | Meets ASTM F519, Very good | ||||
ASTM F519, FAA-AC # 25-29 (glycerin-free), NAVSHIPS 250-1500, Nuclear grade (less than 50 ppm Halogens & Sulfur), P91 Steel Inspection – meets requirement for a water-free couplant, SME Boiler & Pressure Vessel Code (T-533) | -60°F to 350°F (-51°C to 176°C) | The most environmentally friendly commercial ultrasonic couplant available. | 700°F / 371°C | High viscosity stiff gel like fluid | 5 gal / 18.9 liter, two bottles, dispensing faucet | Less than 50 ppm | Meets ASTM F519, Very good | ||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | Carton of (12) 4-oz/118 ml bottles | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | Carton of (12) 8-oz/236.6 ml bottles | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | Carton of (12) 12-oz/355 ml bottles | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | 1 gal / 3.8 liter, with one bottle, dispensing cap | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | 5 gallon / 18.9 liter, two bottles, dispensing faucet | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, Conforms to FAA Circular Advisory AC No: 25-29, NAVSHIPS 250 – 1500, Nuclear grade (less than 50 ppm Halogens & Sulfur) | 10°F to 220°F (-12°C to 104°C) | Medium viscosity | 55 gal / 208 liter drum | Less than 50 ppm | 8.0 nominal at 20°C | ||||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, FAA AC #25-29 (Glycerin-free), NAVSHIPS 250-1500 | 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gauging applications. | Medium viscosity gel | 1 gal / 3.8 liter, with one bottle, dispensing cap | Less than 50 ppm | Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water. | 8.0 nominal at 20°C | |||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, FAA AC #25-29 (Glycerin-free), NAVSHIPS 250-1500 | 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gauging applications. | Medium viscosity gel | 5 gal / 18.9 liter, two bottles, dispensing faucet | Less than 50 ppm | Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water. | 8.0 nominal at 20°C | |||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, FAA AC #25-29 (Glycerin-free), NAVSHIPS 250-1500 | 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gauging applications. | Medium viscosity gel | 7- gallon/26.5 liter pail with lid and pour spout | Less than 50 ppm | Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water. | 8.0 nominal at 20°C | |||||
ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, FAA AC #25-29 (Glycerin-free), NAVSHIPS 250-1500 | 18°F to 120°F (-8°C to 50°C) for most flaw detection and thickness gauging applications. | Medium viscosity gel | 55 gal / 208 liter drum | Less than 50 ppm | Wash with water or wipe with paper or cloth rag before couplant dries. If couplant has dried, pressure wash or use brush and running water. | 8.0 nominal at 20°C | |||||
-18˚ to 224˚F (-28˚ to 107˚C) | Medium flowable gel | Carton of twelve 12 oz / 355 ml bottles | Less than 50 ppm | 8.0 nominal at 20°C | |||||||
-18˚ to 224˚F (-28˚ to 107˚C) | Medium flowable gel | 1 gallon / 3.8 liter cubitainer | Less than 50 ppm | 8.0 nominal at 20°C | |||||||
-18˚ to 224˚F (-28˚ to 107˚C) | Medium flowable gel | 5 gallon / 19 liter cubitainer | Less than 50 ppm | 8.0 nominal at 20°C | |||||||
-18˚ to 224˚F (-28˚ to 107˚C) | Medium flowable gel | Carton of twelve 12 oz / 355 ml bottles | Less than 50 ppm | 8.0 nominal at 20°C |