Fluke 283FC True RMS Wireless Multimeter, CAT III 1500 V, CAT IV 1000 V

Part Number : 283FC

Brand :
Fluke

Whether you work with utility-scale solar PV arrays, wind power, electric railways, or data centers, this digital multimeter is ideal for technicians working in any DC environment up to 1500 V. In addition, this enhances your safety and increases productivity while giving you accurate, reliable, and repeatable results.

View all

KWD 157.940


Quantity



Description
Specifications
Downloads
Related products

Description

Fluke 283FC OffersThe 283 FC includes TL175-HV CAT III 1500 V/CAT IV 1000 V safety-rated silicone TwistGuard test leads for working in higher voltage environments without compromising safety, giving you more flexibility when testing voltage, millivoltage, resistance, continuity, or capacitance. The backlit LCD screen and illuminated keypad make it easier to work in various lighting conditions while the magnetic hanging kit frees up your hands while testing. The 283 FC also includes a custom hard carrying case that protects your investment while you transport it.FeaturesMeasure safely with CAT III 1500 V/CAT IV 1000 V safety rated multimeterIncludes TL175-HV CAT III 1500 V/CAT IV 1000 V safety rated premium test leadsVisual and audio polarity indicators with on/off function help prevent accidental wiring issuesUser-defined limit gauge helps you make quick go/no-go troubleshooting decisionsHighly accurate voltage measurements for precise frontline troubleshootingCurrent measurements up to 60 A AC/DC for safely troubleshooting individual strings with of moduleswith greater accuracy (when using a283 FC wireless current clamp)Visual and audio polarity indicators with on/off function help prevent accidental module wiring issuesUser-defined limit gauge helps you make quick go/no-go troubleshooting decisionsUnique multimeter readiness self-check helps ensure your meter is ready to testSave and log measurements to internal memory and view them on your mobile device via Fluke Connect™User-Defined Limit GaugeOn large-scale PV projects where you’re taking repetitive measurements and expect consistent results, the user-defined limit gauge becomes a vital time-saving tool. The adjustable limit gauge can trigger audio and visual indications whenever a measurement falls outside your expected range. This saves you time letting you quickly evaluate measurement results, increasing your confidence in the system's performance, and helping to identify potential issues that need to be addressed.With the dedicated limit gauge button, you can easily turn the limit gauge warnings on and off, set up new measurement parameters, or select from previously used parameter profiles. This customization streamlines troubleshooting, allowing you to quickly identify measurement deviations or errors, and helps maintain optimal solar installation performance.Unique Multimeter Readiness Self-CheckThe size and location of utility-scale solar sites can present unique challenges whether they’re logistical, environmental, or testing related. Because of that, you want to have confidence that your meter is fully functional, capturing the right data every time so you don’t have to do the same job twice. The 283 FC features a unique integrated multimeter readiness selfcheck, that ensures your meter is in proper working order before you take your next reading. This quick self-check is an additional readiness test that gives you valuable insight to the status of your meter’s calibration, battery life availability, test lead functionality, and AC/DC voltage measurement functionality so you can be confident that your meter is ready to work when you are.Logging/SavingThe 283 FC offers convenient logging and saving features that set it apart from other digital multimeters. With a built-in real-time clock, each measurement can be time- and date-stamped for accurate recordkeeping. The multimeter has internal memory to save and log measurements, which can then be easily transferred to Fluke Connect for further analysis. Additionally, you have the flexibility to customize logging durations and intervals, ensuring the logging process matches the specific needs of the system you are testing.Fluke Connect™ with Fluke Cloud™ StorageFluke Connect™ compatibility provides convenient features to enhance your troubleshooting experience. As part of the Fluke Connect family, the 283 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email. The table view feature organizes measurements, notes, and images in a clear and efficient manner, making it easier to reference data, identify issues, and generate reports for customers. Fluke Connect™ with Fluke Cloud™ Storage streamlines your workflow and ensures accurate data storage and organization.ApplicationsTesting voltage, millivoltage, resistance, continuity, or capacitance on inverters, combiner boxes, PV arrays, or individual PV modules.Frontline troubleshooting of 1500 V DC systems such as utility-scale solar photovoltaic (PV) arrays, wind power installations, electric railways, or data centers.Logging and saving measurements to internal memory or Fluke Connect to perform later detailed analysis.Streamlining troubleshooting with the use of the user-defined limit gauge setting, allowing you to quickly identify measurement deviations or errors, and helping to maintain optimal performance.Railway Electrification: Powering high-speed, metro, and suburban trains.Solar Power Systems: Used in utility-scale solar farms and inverters for improved efficiency.EV Charging Stations: High-power DC fast chargers for buses and commercial vehicles.Traction Substations: Converting high-voltage AC to DC for rail systems.Industrial Equipment: Powering specialized DC motors in heavy industries.

Downloads

Fluke_Multimeter_Datasheet_26.pdf

pdf

Specifications

AC Volts
Range: 6.000 V Resolution: 0.001 V Accuracy: 1.0% + 3 (45 Hz to 500 Hz) Range: 60.00 V Resolution: 0.01 V Accuracy: 1.0% + 3 (45 Hz to 500 Hz) Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0% + 3 (500 Hz to 1 kHz) Range: 1000 V Resolution: 1 V Accuracy: 2.0% + 3 (500 Hz to 1 kHz)
DC Volts
Range: 6.000 V Resolution: 0.001 V Accuracy: 0.09% + 3 Range: 60.00 V Resolution: 0.01 V Accuracy: 0.09% + 3 Range: 600.0 V Resolution: 0.1 V Accuracy: 0.15% + 2 Range: 1500 V Resolution: 1 V Accuracy: 0.15% + 2
DC mV
Range: 600.0 mV Resolution: 0.1 mV Accuracy: 0.09% + 2
AC mV
Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0% + 3 (45 Hz to 500 Hz) Range: 600.0 mV Resolution: 0.1 mV Accuracy: 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range: 600.0 Ω Resolution: 1 Ω
Resistance
Range: 600.0 Ω Resolution: 0.1 Ω Accuracy: 0.5% + 4 Range: 6.000 kΩ Resolution: 0.001 kΩ Accuracy: 0.5% + 4 Range: 60.00 kΩ Resolution: 0.01 kΩ Accuracy: 0.5% + 4 Range: 600.0 kΩ Resolution: 0.1 kΩ Accuracy: 0.5% + 4 Range: 6.000 MΩ Resolution: 0.001 MΩ Accuracy: 1.5% + 4 Range: 50.00 MΩ Resolution: 0.01 MΩ Accuracy: 1.5% + 4
Capacitance
Range: 1000 nF Resolution: 1 nF Accuracy: 1.2% + 2 Range: 10.00 μF Resolution: 0.01 μF Accuracy: 1.2% + 2 Range: 100.0 μF Resolution: 0.1 μF Accuracy: 10% typical Range: 9999 μF Resolution: 1 μF Accuracy: 10% typical
Frequency
Range: 99.99 Hz Resolution: 0.01 Hz Accuracy: 0.1% + 2 Range: 999.9 Hz Resolution: 0.1 Hz Accuracy: 0.1% + 2 Range: 9.999 kHz Resolution: 0.001 kHz Accuracy: 0.1% + 2 Range: 99.99 kHz Resolution: 0.01 kHz Accuracy: 0.1% + 2
AC VA (45 to 500 Hz)
Range: 360.0 VA Resolution: 0.1 VA Accuracy: 2% + 1.0 VA Range: 3.600 kVA Resolution: 0.001 kVA Accuracy: 2% + 1.0 kVA Range: 36.00 kVA Resolution: 0.01 kVA Accuracy: 2% + 0.15 kVA Range: 60.00 kVA Resolution: 0.1 kVA Accuracy: 2% + 0.15 kVA
DC VA
Range: 360.0 VA Resolution: 0.1 VA Accuracy: 2% + 1.0 VA Range: 3.600 kVA Resolution: 0.001 kVA Accuracy: 2% + 1.0 kVA Range: 36.00 kVA Resolution: 0.01 kVA Accuracy: 2% + 0.15 kVA Range: 90.00 kVA Resolution: 0.1 kVA Accuracy: 2% + 0.25 kVA
Operating Temperature
-10 to 60°C (14 to 140°F)
Storage Temperature
-30 to 70°C (-22 to 158°F)
Humidity (without condensation)
0 to 90%, 10 to 30°C (50 to 86°F) 0 to 75%, 30 to 40°C (86 to 104°F) 0 to 45%, 40 to 60°C (104 to 140°F)
Electromagnetic compatibility
IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A
Overvoltage category
CAT III 1500 V, CAT IV 1000 V
Agency approvals
ETL (AMER and EMEA), CSA (APAC), CE, UK CA
Drop test
2 m (6.5') drop test
Ingress Protection
IP52
Counts
6000
Battery Life
> 150 hours typical, without backlight (Alkaline, 3 AA) > 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA)
Dimensions
22.5 x 10.5 x 5.7 cm (8.8 x 4.1 x 2.2")
Weight
0.7 kg (1.5 lb)
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×
Chat with Us