Hanna Instruments Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter, HI98195

Part Number : HI98195

Brand :
Hanna Instruments

The HI98195 is a waterproof portable logging multiparameter meter that monitors up to 10 different water quality parameters including 5 measured and 5 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The complete system is simple to setup and easy to use.

View all

KWD 418.500


Quantity



Description
Specifications
Downloads
Related products

Description

The HI98195 Multiparameter Waterproof Meter is engineered for reliability and versatility in water quality monitoring. With the ability to measure pH, ORP, conductivity, temperature, and pressure, this portable meter is ideal for applications such as industrial water treatment, aquaculture, and field environmental analysis. Its rugged waterproof design ensures durability in demanding conditions, while the intuitive interface and backlit LCD make operation straightforward even in low-light environments. The advanced multi-sensor probe ensures accurate and simultaneous readings for comprehensive water analysis. With enhanced data logging capabilities, the HI98195 is the perfect tool for professionals seeking dependable water quality monitoring.

Features

• Multi-Parameter Display • Multi-sensor Probe • USB Connection

Probe Details

The HI7698195 is a multiparameter pH/EC/Temperature probe for use with the HI98195 portable meter. It features a quick connect that makes a waterproof connection with the meter. Sensors are automatically recognized by the probe and meter when connected. Any ports not used on the probe will not have the parameter displayed on the meter. Sensor replacement is quick and easy with field replaceable, screw type connectors that are color-coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. It’s rugged, waterproof design makes it ideal for field use.

Rugged Carrying Case

The HI98195 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.

Downloads

MAN98194_05_19_crop.pdf

pdf

Specifications

SKU
HI98195
pH Range
0.00 to 14.00 pH
pH Resolution
0.01 pH
pH Accuracy @ 25°C / 77°F
± 0.02 pH
pH Calibration
automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range
± 600.0 mV
mV Resolution
0.1 mV
mV Accuracy
± 0.5 mV
ORP Range
± 2000.0 mV
ORP Resolution
0.1 mV
ORP Accuracy (@25°C/77°F)
± 1.0 mV
ORP Calibration
automatic at one custom point (relative mV)
Temperature Range
-5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K
Temperature Resolution
0.01 °C; 0.01 °F; 0.01 K
Temperature Accuracy @ 25°C / 77°F
± 0.15 °C; ± 0.27 °F; ±0.15 K
Temperature Calibration
automatic at one custom point
EC Range
0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm)
EC Resolution
auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01
EC Accuracy @25°C/77°F
±1% of reading or ±1 µS/cm whichever is greater
EC Calibration
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range
0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor)
TDS Resolution
manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt)
TDS Accuracy @ 25°C / 77°F
±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration
based on conductivity calibration
Resistivity Range
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity Accuracy (@25°C/77°F)
dependent on resistivity reading
Resistivity Calibration
based on conductivity calibration
Salinity Range
0.00 to 70.00 PSU
Salinity Resolution
0.01 PSU
Salinity Accuracy (@25°C/77°F)
±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration
based on conductivity calibration
Temperature Compensation
automatic from -5 to 55 °C (23 to 131 °F)
Log Feature
45,000 records (continuous logging or log-on-demand of all parameters)
Connectivity
USB to PC with HI9298194 Hanna software installed
GLP
Yes
Power Supply
1.5V AA batteries (4)
Power Consumption
approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment
1 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions
186 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight
401 g (14.2 oz.)
Ordering Information
HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.
Warranty
2 years
Recommended Probe
HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×