Fluke 773 CAL Milliamp Process Clamp Meter with calibration certificate

Part Number : 773 CAL

Brand :
Fluke

The Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4 to 20 mA signals five times faster than traditional multimeters, without breaking the loop. It calculates the current process through a section.

View all

KWD 622.480


Quantity



Description
Specifications
Downloads
Related products

Description

Fluke 773 CAL OffersThe 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems. This clamp meter sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1 to 5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.Advanced loop troubleshooting with the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing the transmitter. You can also apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators. Moreover, it offers mA or voltage output linear ramp or 25% step output.FeaturesSource 4 to 20 mA signals for testing control system I/O or I/PsSimulate 4 to 20 mA signals for testing control system I/OMeasure 4 to 20 mA signals with in-circuit measurementSimultaneously measure mA in-circuit with 24 V loop power for powering and testing transmittersSource mA output signals in a linear ramp or 25% step outputAutomatically change the 4 to 20 mA output for remote testingScaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp: Enables a logging DMM (289) or other device to record the 4 to 20 mA signal without breaking the loopmA in/out: Simultaneously measure the mA signal with the clamp and source a mA signalApply a mA input signal to a device and measure its’ 4 to 20 mA output on devices such as valves or mA isolatorsPower saving features, auto-off, backlight timeout extend battery lifeDC voltage measurement to verify 24 V power supplies or voltage I/O signalsSource dc voltage to test input devices that accepts 1 to 5 volt or 0 to 10 volt signalVoltage output linear ramp or 25% step output: Automatically change the voltage output for remote testingBest in class accuracy of 0.2%Delivers 0.01 mA resolution and sensitivityApplicationsHVAC/R SystemsOil and GasPharmaceuticalsProcess Plants

Downloads

773 CAL.pdf

pdf

Specifications

mA Measure
Yes
Jaw
Yes
In Circuit
Yes
mA Source
  • Yes
  • Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum mA drive: 24 mA into 1000 ohms
mA Sim
Yes
Loop Power
Yes
24 V
Yes
DC V Source
Yes
0 to 10 V
Yes
DC V Measure
Yes
0 to 30 V
Yes
Scaled mA Output to mA Input
Yes
mA In/Out
Yes
mA measurement
Resolution: 0 to 20.99 mA Accuracy: 0.2% + 5 counts Notes: Measured by clamp Resolution: 21.0 mA to 100.0 mA Accuracy: 1% + 5 counts Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Measured in series with test jacks
mA simulate
Resolution: 0 to 24.00 mA Accuracy: 0.2% + 2 counts Notes: Maximum voltage 50 V DC
Voltage source
Resolution: 0 to 10.00 V DC Accuracy: 0.2% + 2 counts Notes: 2 mA maximum drive current
Voltage measure
Resolution: 0 to 30.00 V DC Accuracy: 0.2% + 2 counts
Influence of earth’s field
<0.12 mA
Vibration requirements
Random 2 g, 5 Hz to 500 Hz
Drop test
Passes 1 meter drop test (except the jaw)
EMI, RFI, EMC
Meets applicable requirements in EN61326-1 Note: For current measurement w/jaw, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m
IP Rating
IP 40
Temperature Coefficients
0.1(/°C x specified accuracy for temperature < 64.4°F (18°C) or > 82.4°F (28°C))
Environmental Conditions
Operating temperature: 14 to 122 °F (-10 to 50 °C) Storage temperature: -13 to 140 °F (-25 to 60 °C) Operating humidity: < 90% @ < 86°F (30°C); < 75% @ 86 to 131 °F (30 to 55°C) Operating altitude: 0 to 2000 m