Fluke 717-100G Pressure Calibrator, -12 to 100 PSI

Part Number : 717-100G

Brand :
Fluke

Pressure switch test function captures set, reset and Deadband values of a pressure switch. Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24V loop power.

View all

KWD 679.320


Quantity



Description
Specifications
Downloads
Related products

Description

Fluke 717-100G Offers Fluke 717-100G Pressure Calibrator is a compact, lightweight and easy to carry calibrator that delivers outstanding performance, durability and reliability. The Fluke 717 Calibrator is EMI tolerant, dust and splash resistant and features a removable battery door for quick battery changes. The Fluke 717 simultaneously measures pressure and mA and delivers 24 volt loop supply while measuring mA. This new Pressure Calibrator presents cost-effective solutions for highly accurate pressure measurements over a wide range of temperatures. Connect it with any of the Fluke pressure modules to address a wide variety of gauge, differential, absolute, vacuum and dual (compound) pressure applications. Pressure source and milliamp measurement capability to calibrate and maintain almost any pressure device with one tool Error % calculation for quicker pass / fail decision making in the field Best in class mA accuracy (0.015% for better measurement confidence and workload coverage. Features 1/8 NPT female pressure fitting Compatible with non-corrosive Gases and liquids Zero, min, max, and hold functions Calibrate P/I instruments with simultaneous pressure and current measurement Error% calculation of mA measurements for quick pass-fail decisions Long lasting battery life Holster features test lead storage Compatible with Toolpack magnetic hanging system New switch test Applications Petro-Chemical Oil and Gas Pharmaceutical Water and Wastewater Food and Beverage Power Generation .fluke-pressure-calib-select td{border:2px solid #fff;text-align:center}.fluke-pressure-calib-select thead tr td{background:#95abc3;font-weight:bold}.fluke-pressure-calib-select thead tr td:first-child{background:#4a7696}.fluke-pressure-calib-select thead tr:first-child td{background:#4a7696;padding:15px 0 15px}.fluke-pressure-calib-select thead tr:first-child td:nth-child(1n+2) img {max-width:68px}.fluke-pressure-calib-select thead tr:first-child td:first-child{background:#fff}.fluke-pressure-calib-select tbody tr td:first-child{background:#95abc3;text-align:left}.fluke-pressure-calib-select tbody tr:first-child td{background:#d0dbe5;color:#416a86;font-weight:bold}.fluke-pressure-calib-select tbody td:nth-child(even) {background:#d0dbe5}.fluke-pressure-calib-select tbody td:nth-child(odd) {background:#e6ecf2} Application Selection Guide Model number 754 721/?721Ex 719Pro 719 718 717 700G 3130 2700G Dead-weight Testers Application Calibrating pressure transmitters (field) ? ? Ideal ? ? ? ? Calibrating pressure transmitters (bench) ? ? ? ? ? ? Ideal ? Calibrating HART Smart transmitters Ideal Documenting pressure transmitter calibrations Ideal Testing pressure switches in the field Ideal ? ? ? ? ? ? Testing pressure switches on the bench ? ? ? ? ? ? Ideal Documenting pressure switch tests Ideal Testing pressure switches with live (voltage) contacts Ideal Gas custody transfer computer tests ? Ideal ? Verifying process pressure gauges (field) Ideal ? ? ? ? ? ? Verifying process pressure gauges (bench) ? ? ? ? ? ? ? ? Ideal Logging pressure measurements ? Ideal ? Testing pressure devices using a reference gauge Ideal Hydrostatic vessel testing Ideal Leak testing (pressure measurement logging) ? Ideal Pressure Calibration Selection Guide

Downloads

717-100G.pdf_14.pdf

pdf

Specifications

Pressure Range
-12 to 100 PSI, (-850 mbar to 7 bar, -83 to 689.48 kPa)
Pressure Resolution
0.01 psi, 0.1 mbar, 0.01 kPa
Over Pressure
2 X full scale
Loop Power Range
24 V dc
Loop Power Accuracy
+/- 10%
Display
Clear 5 digit LCD
Operating Temperature
-10 to 55 °C
Operating Altitude
3,000 M max
Size
201 mm L x 98 mm W x 52 mm (7.93in. L x 3.86in. W X 2.06in.)
Weight
22 oz, approximately 600G with holster
Battery Type
Single 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline