Maximum Voltage Between any Terminal and Earth Ground
1000 V AC
1500 V DC
Electrical Specifications
Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
AC Current: Jaw
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)
Crest factor (50/60 Hz):
2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2% for C.F. >2
AC Current: Flexible Current Probe
Range: 999.9 A; 2500 A
Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)
Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):
2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2% for C.F. >2
Position Sensitivity
Distance from optimum:
A
B
C
i2500-18 Flex:
1.4" (35.6 mm)
2" (50.8 mm)
2.5" (63.5 mm)
Error:
±0.5%
±1%
±2%
DC Current
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
AC Voltage
Range: 600 V; 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 to 500 Hz)
DC Voltage
Range: 600 V; 1500
Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV DC
Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps Frequency: Jaw
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Voltage Frequency
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level:
5 to 20 Hz, ≥5 V
20 to 100 Hz, ≥5 V
100 to 500 Hz, ≥10 V
DC Power
Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)
Resolution: 0.1 kVA, 1 kVA
Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
Resistance
Range: 600 Ω, 6000 Ω, 60 kΩ
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance
Range: 100 μF, 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level: 5 A
Temperature
Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity
Non-condensing <50°F (10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C)
Altitude
Operating: 6561.68' (2000 m)
Storage: 39,370.07' (12,000 m)
Electromagnetic Compatibility (EMC)
International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. Thi
Safety
General: IEC 61010-1, Pollution Degree 2
Measurement:
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range: 2400 to 2483.5 MHz
Output power: <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
Automatic Power Off
20 minutes
Display
Dual display with backlight
Batteries
Two AA IEC LR6 alkaline
Dimensions
Size: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm)
Jaw opening: 1.33" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)