Fluke 3540 FC KIT Three-Phase Power Monitor

Part Number : 3540 FC KIT

Brand :
Fluke

Monitor three-phase systems and stream data to the Fluke Connect Cloud. Measurements include current, voltage frequency, power, apparent power, non-active power, power factor, and total harmonic distortion. Kit includes instrument, power supply, voltage test leads, dolphin clips (4x), 1500A flexible current probe (3x), magnetic hanging kit, WiFi to USB adapter, and color coding set.

View all

KWD 1,283.400


Quantity



Description
Specifications
Downloads
Related products

Description

Fluke 3540 FC KIT OffersPowered from the measurement circuit, configuration checker can automatically correct connection errors. Monitors equipment for changes in key electrical variables. Current, voltage, frequency, and energy consumption fluctuates when machinery experiences excess load. Screen assets for performance or premature wear using the non-invasive 3540 FC. Features Portable device offers scalable, remote power monitoring solution View power measurements from a safe distance Wirelessly collect real-time power values Make data-driven decisions Measures: Single, split, or three phase loads Voltage, current, and frequency Active power, non-active power, and power factor Total harmonic distortion Wireless data collection or internal memory sufficient for 1 week with 1 second data intervals Remotely monitor real-time and historical power variable data Visualize data with software trending, graphing, and timeboxing Auto-generated alarms when power variables deviate from pre-set thresholds Power options: Battery, power supply, or power from the measurement line Size: (W x H x D) 7.8 x 6.6 x 2.2" IP Rating: IP 50; IEC 60529

Downloads

3540 FC KIT.pdf

pdf

Specifications

Operating Temperature
32 to 113°F (0 to 45°C)
Storage Temperature
-4C to 140°F (<20 to 60°C), with battery: -4 to 122°F (-20 to 50°C)
Operating Humidity
<50°F (<10°C) non condensing 50 to 86°F (10 to 30°C) ≤95% 86 to 104°F (30 to 40°C) ≤75% 104 to 113°F (40 to 45°C) ≤45%
Operating Altitude
6500' (2000 m) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage Altitude
39,000' (12,000 m)
IP Rating
IEC 60529:IP50, in connected condition with protection caps in place
Vibration
MIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1
IEC mains input: Overvoltage Category II, Pollution Degree 2 Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
Electromagnetic Compatibility (EMC)
International: IEC 61326-1: Industrial Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless Radio with Adapter
Frequency range: 2412 to 2462 MHz Output power: <100 mW
Single and Three-Phase Topologies
Wiring configurations: 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Voltage Inputs
Number of inputs: 4 (3 phases and neutral) Maximum input voltage: 1000 Vrms (1700 Vpk) phase to neutral
Input Impedance
10 MΩ each phase to neutral
Bandwidth
42.5 Hz to 3.5 kHz
Scaling
  • 1:1, variable
  • 1:1 and variable
Current Inputs
Number of inputs: 3, mode selected automatically for attached sensor
Current Sensor Output Voltage
Clamp: 500 mVrms / 50 mVrms; CF 2.8 Rogowski coil: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Bandwidth(-3 dB)
42.5 Hz to 3.5 kHz
Data Acquisition Resolution
16-bit synchronous sampling
Sampling Frequency
10.24 kHz at 50/60Hz, synchronized to mains frequency
Input Signal Frequency
Mains 50/60 Hz (42.5 to 69 Hz)
Data Storage
Internal flash memory (not user replaceable)
Memory Size
Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.
Measured Parameters
Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
Averaging Interval
1 s
Total Harmonic Distortion
THD for voltage and current is calculated on 25 harmonics
Calculated min/max values times
Voltage: Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz) Current: Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz) Power: 200 ms
Interfaces
USB-A: Firmware updates, max. supply current: 120 mA
WiFi
Supported modes: Direct connection and connection to infrastructure
Security
WPA2-AES with pre-shared key
Power Supply
Voltage Range: Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
Mains Power
Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
Power Consumption
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Standby Power
<0.3 W only when powered using IEC 60320 input
Efficiency
≥68.2 % (in accordance with energy efficiency regulations)
Mains Frequency
50/60 Hz ±15 %
Battery Power
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-Battery Runtime
Up to 4 hr (up to 5.5 hr in energy saving mode)
Color LCD Display
4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty
3540 FC and built-in power supply 2 years (battery not included)
Accessories
1 year
Calibration Cycle
2 years
Dimensions
3540 FC: 7.8 x 6.6 x 2.2" (19.8 x 16.7 x 5.5 cm) Detachable Power Supply: 5.1 x 5.1 x 1.8" (13.0 x 13.0 x 4.5 cm) 3540 FC with Power Supply Attached: 7.8 x 6.6 x 4.0" (19.8 x 16.7 x 9 cm)
Weight
2.5 lb (1.1kg)
Tamper Protection
Kensington lock
Industrial Spare Logo

Industrial Spare
Typically replies within an hour

Industrial Spare
Hi there,

How can I help you?
+96566651231
×
Chat with Us