Fluke 353 True RMS Clamp Meter, 2000 A

Part Number : 353

Brand :
Fluke

Confidently take reliable readings with this clamp meter, and is for use with high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, and rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

View all

KWD 347.200


Quantity



Description
Specifications
Downloads
Related products

Description

Fluke 353 OffersFeatures Reliably handle a wide range of high-current applications with 2000 A AC and DC True RMS, 1400 A AC, and 2000 A DC The large 2.3" (58 mm) jaw capacity is suitable for large or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures 'power-on' surge current with accuracy and repeatability Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A large backlit display allows for easy visibility in low-lit areas Use the display hold feature to capture readings even when the display cannot be viewed Use the low-pass filter to smooth out noisy loads and stabilize readings Fluke Clamp Selection Guide

Downloads

353.pdf

pdf

Specifications

Range
  • 40 A/400 A/2000 A/1400 AC RMS
  • 40 A/400 A/2000 A; 1400 AC RMS
Resolution
  • 10 mA/100 mA/1 A
  • 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz)
Accuracy
  • A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits
  • 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits
  • 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts
Trigger Level for Inrush
0.50 A/5.0 A/5 A
Trigger Level for Hz Filter OFF
2.50 A/2.5 A/8 A
Trigger Level for Hz Filter ON
0.50 A/2.5 A/8 A
Crest Factor
2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A
Measurement Range
5.0 Hz to 1 kHz
Operating Temperature
32 to 122°F (0 to 50°C)
Storage Temperature
-4 to 140°F (-20 to 60°C)
Operating Humidity
0 to 95% (non-condensing)
Operating Altitude
6561.68' (2000 m)
Storage Altitude
32,808.4' (10,000 m)
IP Rating
42 (indoor use only)
Drop Test Requirements
3.28' (1 m)
EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature Coefficients
Current: 0.1% of reading per °C outside 22°C to 24°C Voltage: 0.1% of reading per °C outside 22°C to 24°C
Battery
Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours
Test Leads
Rated to 1000 V
Jaw Size
2.28" (58 mm)
Dimensions
12 x 3.75 x 2" (300 x 98 x 52 mm)