Casella Logging Environmental 1/3 Octave Band Sound Level Meter Kit, Class 1, CEL-633C1/K1
Casella CEL-633C1/K1 is a high-performance 63x Series Sound Level Meter Kit, ideal for occupational and environmental noise monitoring. Features real-time frequency analysis in 1/1 and 1/3-octave bands, audio recording, and compliance with ISO9612 and ISO1996 standards. Ensures precise noise assessment for both industrial and environmental applications.
View all
$ 6720
Lead Time - 3 Weeks, for urgent requirement please contact us.
Description
The CEL-633C1 is a 1/3 Octave Band Sound Level Type I Meter ideal for testing Occupational and Environmental Noise. The 63X Series is designed to make workplace noise measurements as quick and simple as possible. The displayed information can be made as simple or comprehensive as required and all measurement parameters are stored simultaneously, so no incorrect measurements can be made. For environmental noise data can be marked to signify any significant events, the data fromwhich can be removed afterwards in insight software.Up to 60 hours of audio files can be stored, commonly used for noisesource identification. Stored audio can be played back on the instrumentusing headphones or downloaded to Casella insight software. CEL-633C1-K1 is a kit including the relevant instrument, acoustic calibrator (CEL-120), USB download cable, batteries, calibration certificates and an executive kit case. All occupational noise characteristics, as well as those required for environmental monitoring, can be measured simultaneously with the Casella 63x Series sound level metres. The metre is simple to operate and set up, thanks to its intuitive design. The CEL-63X is perfect for sound level monitoring in the workplace or in the environment. For ISO, OSHA, and other standards, pre-configured settings are available, and you can even programme your own. The CEL-63X can measure all parameters with all frequency and time weightings at the same time.
Applications
- Occupational Noise Measurement - Workplace noise assessments according to ISO9612 - Selection of hearing protection - Calculation of noise exposure - Ensuring compliance with workplace noise legislationEnvironmental Noise Measurement - Boundary noise assessments - Noise nuisance complaints - Measurements according to ISO1996, BS4142 - UK Construction Section 61 notices
Key Features
- Ideal for environmental or occupational monitoring - Easy to use switch-on-and-go functionality - Latest digital technology with a high resolution colourTFT display - Pre-configured setups for occupational andenvironmental measurements - Voice notes to annotate measurements - Single measurement range up to 140dB, no rangeadjustment required - Data markers, back erase function and audio recording - Level triggered events for transient measurements - Real-time octave measurements - Simultaneous measurement of all parameters with allfrequency and time weightings - Class 1 - 2GB memory for more than 1 year of data storage - Removable pre-amp - Environmental outdoor kit
Measured Parameters
- Broadband: LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq,LTM3, LTM5, LAE. Workplace dose values are calculated within insightsoftware. - Octaves: LXY, LXeq, LXYmax, 5x Ln% (on CEL-633).Where X is the frequency weighting A, C or Z and Y represents timeweighting Fast (F), Slow (S) or Impulse (I). All weightings simultaneouslymeasured where appropriate. - CEL-633 model additionally stores 5x Ln values in broadbandand octave modes. - For time history data, all parameters are logged for period times plus 6selectable profile parameters (plus 5x Ln values on CEL-633).
Operational Noise Measurements
The CEL-630 Series is designed to make workplace noise measurements as quick and simple as possible. The displayed information can be made as simple or comprehensive as required and all measurement parameters are stored simultaneously, so no incorrect measurements can be made. When the unit is calibrated with the CEL-120 calibrator, the calibration dates and times are stored and downloaded to Casella insight software, validating the accuracy of measurements. Average, peak, and octave band measurements are performed at the same time, so only one measurement needs to be made for all workplace noise applications.
Environmental Noise Measurements
Data can be marked to signify any significant events, the data from which can be removed afterwards in insight software. Up to 60 hours of audio files can be stored, commonly used for noise source identification. Stored audio can be played back on the instrument using headphones or downloaded to Casella insight software. For unattended monitoring, event mode (CEL-633) allows trigger levels (dB) to be set, so additional data (e.g. Leq, Lmax) is stored together with the audio file for later play back or analysis, as well as a profile down to 10ms intervals. An environmental noise monitoring kit is available which protects the instrument and microphone from the weather and allows unattended monitoring for up 10 days.
Specifications
LEGAL DISCLAIMER
All products are 100% genuine and legally purchased from authorized sources. Indspare is not an authorized dealer, agent or affiliate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.indspare.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the rights of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website.