Fluke 719PRO-150G Electric Pressure Calibrator, 150 psi, 10 bar

719PRO-150G.webp

Part Number : 719PRO-150G

Brand : Fluke

Source, simulate, and measure mA signals with this electric pressure calibrator that features an integrated electric pump for one-handed pressure calibration up to 150 psi. Ideally suited to calibrate high-accuracy transmitters, pressure switches, and gauges, the unit features a backlit display and a rugged, handheld design.

View all

$ 5086.99


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Eliminate over-pressurizing and program target pressure for pumping with the pressure calibrator pump limit. Easy to use and versatile, the pressure calibrator features inputs for mA, voltage, switch contacts, and an RTD probe. Integrated Electric Pump - Now to 300 psi, 20 bar The Electric Pressure Calibrator is the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges. The unit includes a full functioning loop calibrator that sources, simulates and measures mA signals and more. The large backlit screen displays three parameters at once. Features Pressure measurement from internal or external sensor Sourced/simulated or measured mA values Electric pump for one handed pressure calibration Best in class pressure measurement uncertainty of 0.025% Measure and source mA with best in class 0.015% accuracy Precision pressure adjust vernier for accurate pressure calibration Variable release rate bleed valve for easy pressure adjustment Programmable pressure calibrator pump limit: eliminates over-pressurization and allows the user to program target pressures for pumping Programmable 3-tiered display for maximum flexibility when displaying pressure, temperature, and electrical parameters of your choice Display backlight Damping, min/max, and % error function Source mA with simultaneous pressure measurement to test valves and I/Ps Simulate mA signals to troubleshoot 4-20 mA loops Test pressure switches with built in switch test function Power transmitters during test using 24 V loop supply with simultaneous mA measurement Proven cleanout ports reduce pump failures Moisture trap included with the unit helps mitigates risk of moisture damage Applications Petro-chemical Oil and gas Pharmaceutical Water and wastewater Food and beverage Power generation .fluke-pressure-calib-select td{border:2px solid #fff;text-align:center}.fluke-pressure-calib-select thead tr td{background:#95abc3;font-weight:bold}.fluke-pressure-calib-select thead tr td:first-child{background:#4a7696}.fluke-pressure-calib-select thead tr:first-child td{background:#4a7696;padding:15px 0 15px}.fluke-pressure-calib-select thead tr:first-child td:nth-child(1n+2) img {max-width:68px}.fluke-pressure-calib-select thead tr:first-child td:first-child{background:#fff}.fluke-pressure-calib-select tbody tr td:first-child{background:#95abc3;text-align:left}.fluke-pressure-calib-select tbody tr:first-child td{background:#d0dbe5;color:#416a86;font-weight:bold}.fluke-pressure-calib-select tbody td:nth-child(even) {background:#d0dbe5}.fluke-pressure-calib-select tbody td:nth-child(odd) {background:#e6ecf2} Application Selection Guide Model number 754 721/?721Ex 719Pro 719 718 717 700G 3130 2700G Dead-weight Testers Application Calibrating pressure transmitters (field) ? ? Ideal ? ? ? ? Calibrating pressure transmitters (bench) ? ? ? ? ? ? Ideal ? Calibrating HART Smart transmitters Ideal Documenting pressure transmitter calibrations Ideal Testing pressure switches in the field Ideal ? ? ? ? ? ? Testing pressure switches on the bench ? ? ? ? ? ? Ideal Documenting pressure switch tests Ideal Testing pressure switches with live (voltage) contacts Ideal Gas custody transfer computer tests ? Ideal ? Verifying process pressure gauges (field) Ideal ? ? ? ? ? ? Verifying process pressure gauges (bench) ? ? ? ? ? ? ? ? Ideal Logging pressure measurements ? Ideal ? Testing pressure devices using a reference gauge Ideal Hydrostatic vessel testing Ideal Leak testing (pressure measurement logging) ? Ideal Pressure Calibration Selection Guide

Downloads

719PRO-150G.pdf_24.pdf

pdf

Specifications

Range
  • -12 to 150 psi / -0.8 to 10 bar
  • 0 to 24 mA DC
  • 30 V DC
  • -50 to 150 °C (-50 to 302°F)
  • 24 V DC
Resolution
  • 0.01 psi, 0.001 bar
  • 0.001 mA
  • 0.001 V
  • 0.01 to 0.01°F
Accuracy
  • ±0.025% of full scale, 6 months ± 0.035% of full scale, 1 year dry air and non-corrosive gas only
  • ± 0.015% of reading ± 2 counts
  • ± 0.1°C (0.2°F)
  • 24 mA at 24 V
  • Add ± 0.002% F.S./°C for temps outside of 15 to 35°C No effect on accuracy on all functions from 15 to 35°C
Temperature Effect
Add ± 0.002% F.S./°C for temps outside of 59 to 95°F (15 to 35°C) No effect on accuracy on all functions from 15 to 35°C
Max Load in mA Source
1000 Ω
Max Voltage in mA Simulate
26 V DC
Pressure
1/8" female NPT
Electrical
Standard banana jacks
RTD
4 pin miniature circular
External Module
6 pin miniature circular
Battery
8 x standard Alkaline AA batteries
Battery Life
300 pump cycles to 150 PSI minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum
Dimensions
9.5 x 4.4 x 2.8" (24.13 x 11.18 x 7 cm)
Weight
With holster 2.5 lb (1.2 kg)