Fluke 1529 Chub-E4 Standards Thermometer, 4-channel

1529-156.webp

Part Number : 1529-156

Brand : Fluke

Featuring four inputs for reading four sensors simultaneously, this standards thermometer can configure those inputs in three ways, according to preference. Perfect for benchtop thermometry, store up to 8000 readings at user-selected intervals and choose statistical functions such as averages, standard deviations, and spreads.

View all

$ 7259


Quantity In Stock



Description
Specifications
Downloads
Related products

Description

Fluke 1529-156 Offers Impressive performance with a rugged design, this standards thermometer is ideal for reading thermocouples, PRTs, and thermistors all from the same device. PRTs and thermistors connect easily to the thermometer using Fluke Calibration’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations, and thermocouples connect using standard or miniature terminations. Measurements are taken each second simultaneously or sequentially, and a special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second. This Chub-E4 thermometer displays 8 user-selected data fields from any channel. Features 4 channels for PRTs, thermistors and thermocouples Logs up to 8,000 readings with date and time stamps Battery provides 8 hours of continuous operation

Downloads

Fluke_Temperature_Datasheet_23.pdf

pdf

Specifications

Inputs
2 channels PRT/thermistor and 2 channels thermocouple or 4 channels PRT/thermistor or 4 channels thermocouple PRT/thermistor channels accept 2,3, or 4 wires Thermocouple channels accept B, E, J, K, N, R, S, T, and Au-Pt thermocouple types
Temperature Range
PRT: -308 to 1760°F (-189 to 960°C) Thermistor: -58 to 302°F(-50 to 150°C) Thermocouple: -454 to 3272°F(-270 to 1800°C)
Measurement Range
PRT: 0 to 400 Ω Thermistor: 0 to 500 kΩ Thermocouple: –10 to 100 mV
Resistance/Voltage Accuracy
PRT: 0 to 20 Ω: ±0.0005, 20 to 400 Ω: ±25 ppm of reading Thermistor: 0 to 5 kΩ: ±0.0005 kΩ, 5 to 200 kΩ: ±100 ppm of reading, 200 to 500 KΩ: ±300 ppm of reading Thermocouple: –10 to 50 mV: ±0.005 mV, 50 to 100 mV: ±100 ppm of reading (Internal RJC: ±0.25°C)
PRT
±0.004°C at –100°C ±0.006°C at 0°C ±0.009°C at 100°C ±0.012°C at 200°C ±0.018°C at 400°C ±0.024°C at 600°C
Thermistor
±0.0025°C at 0°C ±0.0025°C at 25°C ±0.004°C at 50°C ±0.010°C at 75°C ±0.025°C at 100°C
Thermocouple (Type Ext./Int.RJC)
B: ±0.6°C/±0.6°C E: ±0.07°C/±0.25°C J: ±0.1°C/±0.35°C K: ±0.15°C/±0.4°C N: ±0.15°C/±0.3°C R: ±0.4°C/±0.5°C S: ±0.5°C/±0.6°C T: ±0.1°C/±0.3°C
Temperature Resolution, Typical
PRT: 0.001° Thermistor: 0.0001° Thermocouple: 0.01 to 0.001°
General Specifications
Operating Range
Measurement Interval
0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval
Excitation Current
PRT: 1mA (reversing) Thermistor: 2 and 10 μA, automatically selected Thermocouple: N/A
Display
1.3 x 5” (33.02 x 127 mm) backlit LCD graphical display
Display Units
°C, °F, K, Ω, KΩ, mV
Data Logging
Up to 8000 time-and-date-stamped measurements can be logged
Logging Intervals
0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
Averaging
Moving average of most recent 2 to 10 readings, user selectable
Statistical Data
Average, standard deviation, minimum, maximum, spread, N, difference (delta)
Probe Connection
PRT and thermistor: Patented DWF connectors accepts spade lug, bare-wire, or banana plug terminations Thermocouple: Universal receptacle accepts miniature and standard connectors
Communications
RS-232 port included, IEEE-488 (GPIB) optional
AC Power
100 to 240 V AC, 50-60 Hz, 0.4 A
DC Power
12 to 16 VDC, 0.5 A (battery charges during operation from 14.5 to 16 V DC, 1.0 A)
Battery
NiMH, 8 hours operation typical without backlight, 3 hours to charge, 500 cycles
Size
4.0 x 7.5 x 8.2” (102 x 191 x 208 mm)
Weight
4.5 lbs. (2 kg)
Characterization
PRT: ITS-90, PT-100 (ASTM E1137, DIN 43760, IEC-751), Callendar-Van Dusen Thermistor: Steinhart-Hart, YSI-400 Thermocouple: NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial